MASON C-RE 585

CRE585

Mason

New

MASON C-RE 585 Injection mortar is approved for:
1) Diamond-drilled holes
2) Water-filled drill holes
2) Seismic applications C1, C2

$0.00

-20%

+ -

Add to wishlist

MASON C-RE (Pure Epoxy Chemical Anchor) - Installation of Reinforcing Bars





MASON C-RE Pure Epoxy Chemical Injection Anchor - On Site Tensile Pull Out Test

Description

MASON C-RE 585 mortar is a 2-component reaction resin mortar based on a pure epoxy, it is characterized, by a high range of applications with an installation temperature from +5.C and a service temperature up to 72.C as well as by high chemical resistance for applications in extreme ambiences e.g. in swimming pools(chlorine) or closeness to the sea(salt).

Features

European Technical Assessment Certification
4 hrs CSTB Fire Resistance Tested
HDB Material List - Singapore
Ultimate Performance Tested by SETSCO Singapore
KMITL Thailand Tested
High Viscosity, Long Working Time
Applicable in Cracked and Un-cracked Concrete
Damp, Wet and Under Water Holes Applicable
High bending strength 47 N/mm2 acc. to EN 196 Part 1
High compressive strength 137 N/mm2 acc. to EN 196 Part 1
High Chemical Resistance
Non-Shrinkage, Low odour
Resealable UV Resistance Hard Plastic Cartridge

Special Properties and Benefits

  • Heavy anchoring - doweling and post-installed rebar connection
  • Hammer drilled and diamond drilled holes applicable
  • High viscosity ; ideal for overhead application
  • Suitable for attachment point close to the edge, since anchoring is free of expansion forces
  • Suitable for dynamic load; Cracked concrete applicable
  • Strong and secure anchoring even under water; water filled bore holes applicable
  • Water-impermeable acc. to DIN EN 12390-8
  • Fire resistance and high chemical resistance
  • Low shrinkage: ideal for larger annular gap
  • Low odour; ideal for indoor application
  • Safe for use as a component in a drinking water system
  • Flexible working time at elevated temperatures
  • Resealable cartridge: can be reused up to the end of the shelf life

Reactivity

Temperature of base material

Gelling and working time

Full curing time in dry base material

Full curing time in wet base material

+5°C

120 Min.

50 hrs

100 hrs

+10°C

90 Min.

30 hrs

60 hrs

+20°C

30 Min.

10 hrs

20 hrs

+30°C

20 Min.

6 hrs

12 hrs

+40°C

12 Min.

4 hrs

8 hrs

Application and Intended Use

Base Material

Cracked concrete, uncracked concrete, light concrete, porous concrete, solid masonry, natural stone; hammer drilled and diamond drilled holes

Anchor Elements

Threaded rods (zinc plated or hot dip galvanized, stainless steel and high corrosion resistance steel), reinforcing bars, internal threaded rods, profile rod, steel section with undercuts (e.g. perforated section)

Temperature Range

+5°C up to +40°C temperature of the base material; cartridge temperature min. +5°C; optimal +20°C; -40°C to +72°C base material temperature after full curing

Suitable Application

Suitable for facades, roofs, metal construction; metal profiles, column, beam, console, railing, sanitary devices, cable trays, piping, post-installed rebar connection (reconstruction or reinforcement),building reconstruction and renovation, etc.

You need to Login to be able view/download the files